1. Intermittent means the entrance of the maximum
pressure; continuous working pressure means the differential
pressure
2. Motor should not work under the highest pressure and the
maximum speed
3. The running time should not exceed 10% under intermittent
working conditions
4. Recommending N68 anti-wear hydraulic oil, viscosity
37-73cSt, cleanliness ISO18/13.
5. The Maximum working temperature is 80 °
6. One hour running time under 40% of maximum working pressure
is recommended before full capacity working.
7. The maximum allowable back pressure is 10MPa, but the